Product Details:
Payment & Shipping Terms:
|
Nominal Tube Voltage: | 125KV | Nominal Focal Spot: | 1.0/2.0 |
---|---|---|---|
Exposure Rating: | 20KW/40KW | Target Angle: | 16° |
Model: | SRMWTX70-1.0/2.0-125 | Rotation Speed: | 2800RPM |
High Light: | dual focus x ray tube,conventional x ray tube |
20KW/40KW 125KV Rotating Anode X-ray Tube for CR or DR Machine
INSERT SPECIFICATIONS
Maximum Operating Voltage...............................................................................125KV
Focal Spot Size...................................................................................................1.0/2.0
Diameter...............................................................................................................72mm
Target Material...................................................................................................... RTM
Anode Angle.............................................................................................................16°
Rotation Speed...............................................................................................2800RPM
Heat Storage.....................................................................................................140kHU
Maximum Continuous Dissipation.........................................................................475W
Filament Characteristics
Small filament...........................................................................................Ifmax=5.1A
Big filament ..............................................................................................Ifmax=5.1A
Inherent Filtration......................................................1mmAL/ 75KV(IEC60522/1999)
Maximum Power(0.1s)...............................................................................20KW/40KW
TECHNICAL DATA
OUTLINE DRAWING:
Competitive Advantage:
Standard speed anode rotation with silenced bearings
High density compound anode (RTM)
Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime
Detailed Images
For more type of our rotating anode x-ray tubes, please see the following chart:
Type | Focal spot |
Max rating(kW) | Max voltage (kV) |
Max tube current (mA) |
Target angle() |
Target material |
Dimension (mm) |
Rotation rate (W/min) |
Max anode heat content (KHU) |
Max anode continuous heat dissipation(W) |
MWTX64-0.3/0.6-130 | 0.3/0.6 | 5/17(50Hz) | 130 | 110/360 | 10° | RTM | 218×Φ80 | 2800 | 210 | 300 |
MWTX64-0.6/1.3-130 | 0.6/1.3 | 11/32(50Hz) | 130 | 250/700 | 15° | RTM | 218×Φ80 | 2800 | 110 | 300 |
MWTX64-0.8/1.8-130 | 0.8/1.8 | 12/33(50Hz) | 130 | 180/480 | 15° | RTM | 218×Φ80 | 2800 | 70 | 175 |
MWTX64-0.6/1.3-130H | 0.6/1.3 | 20/54(150Hz) | 130 | 400/880 | 15° | RTM | 218×Φ80 | 2800/8400 | 110 | 300 |
MWTX70-1.0/2.0-125 | 1.0/2.0 | 21/42.5(50Hz) | 125 | 340/570 | 16 | RTM | 250×Φ108 | 2800 | 140 | 475 |
MWTX71-0.6/1.2-125 | 0.6/1.2 | 20/40(50Hz) | 125 | 350/750 | 12.5 | RTM | 250×Φ108 | 2800 | 150 | 500 |
MWTX72-1.0/2.0-125 | 1.0/2.0 | 20/40(50Hz) | 125 | 380/800 | 16° | TM | 250×Φ108 | 2800 | 140 | 410 |
MWTX72-1.0/2.0-150 | 1.0/2.0 | 20/40(50Hz) | 150 | 380/800 | 16° | TM | 250×Φ108 | 2800 | 140 | 410 |
MWTX73-0.6/1.2-150 | 0.6/1.2 | 20/50(50Hz) | 150 | 400/1fff | 12° | RTM | 250×Φ108 | 2800 | 300 | 750 |
MWTX74-0.6/1.2-150 | 0.6/1.2 | 20/46(50Hz) | 150 | 370/760 | 12 | RTM | 250×Φ108 | 2800 | 150 | 475 |
MWTX75-0.6/1.2-150 | 0.6/1.2 | 20/50(50Hz) | 150 | 300/700 | 12 | RTM | 250×Φ108 | 2800 | 220 | 750 |
MWTX76-0.6/1.2-150 | 0.6/1.2 | 20/50(50Hz) | 150 | 300/700 | 12 | RTM | 250×Φ108 | 2800 | 300 | 870 |
MWTX78-0.6/1.5-125 | 0.6/1.5 | 18/47.5(50Hz) | 125 | 260/750 | 14° | RTM | 250×Φ108 | 2800 | 200 | 410 |
MWTX90-0.6/1.2-150 | 0.6/1.2 | 19/50(50Hz) | 150 | 350/800 | 12° | RTM | 265×Φ120 | 2800 | 300 | 500 |